Kemppi AX MIG Welder Operating Manual page 86

Table of Contents

Advertisement

CycleOn
ArcOn
TouchSensed
PowerSourceReady
Error
WeldingSystemReady
LocalRemote
AutoManual
GasFlowOk
GateDoorOpen
CollisionDetected
DigitalInput [1...16]
© Kemppi
Welding cycle is not ongoing
Welding arc is not established
Touch is not detected
Power source is busy
No error or only a warning
System is not ready
Remote
Manual
Gas flow rate is below the min-
imum gas flow rate
Gate door is closed
Collision is not detected
Digital input is in low state
86
Welding cycle is ongoing
Welding arc is established
Touch is detected
Power source is ready
There is an error in the system
System is ready
Local
Auto
Gas flow rate is above the min-
imum flow rate or the gas flow
sensor is OFF
Gate door is open
Collision is detected
Digital input is in high state
AX MIG Welder
Operating manual - EN
Indicates whether welding
cycle is ongoing. The welding
cycle includes also pre gas,
creep start, crater fill and post
gas phases.
Indicates whether welding arc
is established.
Indicates if a touch is detected
between the touch tool and
the work piece. The touch
sensor must be set active with
the TouchSensorOn control
bit.
Indicates whether the power
source is ready to start a new
weld. The power source is
ready when the robot has not
requested welding and crater
fill is not ongoing.
Indicates whether there is an
error in the system that pre-
vents welding
Indicates whether the welding
system is ready to be used for
welding. The system is ready
when all necessary devices are
present and no error is active.
Not in use. State is always 1.
Not in use. State is always 0.
Indicates if the gas flow rate is
above the minimum gas flow
rate or if the gas flow sensor is
set to OFF.
Indicates if the gate door to
the robotic cell is open or
closed.
Wire feeder's collision sensor
status. The collision sensor
must be set ON in AX Man-
ager.
Digital input status.
To use digital inputs 1...8, the
DIO (Digital Input/Output)
card must be installed in the
add-on card slot 1.
To use digital inputs 9...16,
the DIO card must be installed
in the add-on card slot 2.