Control Panel: System Settings - Kemppi Master M 353 Operating Manual

Table of Contents

Advertisement

Crater fill
- Crater fill start level
- Crater fill time
- Crater fill end level
- Crater fill 4T timer
Touch Sense Ignition
WiseFusion
Pulse / DPulse / MAX Position welding parameters (Master M 355 only)
The parameters listed here are available for adjustment with the pulse and MAX Position welding processes in addition to the
MIG and 1-MIG welding parameters. For more information on the processes, refer to "Additional guidance to functions and fea-
tures" on page 47.
Parameter
Pulse current %
DPulse frequency
DPulse ratio
MAX Position frequency

3.3.7 Control panel: System settings

© Kemppi
ON/OFF
Default = OFF
10 ... 150 %, step 1
Default = 100 %
0.1 ... 10.0 s, step 0.1
Default = 1.0 s
10 ... 150 %, step 1
Default = 10 %
ON/OFF
OFF/ON
Default = OFF
OFF/ON
Default = OFF
Parameter value
-10 ... 15 %
Default = 0 %
0.4 ... 8.0 Hz
Default = 2 Hz
10 ... 90 %
Default = 35 %
-0.5 ... 0.5 Hz
Default = 0 Hz
43
Operating manual - EN
When welding with high power, a crater
is usually formed at the end of the weld.
The Crater fill function decreases the
welding power / wire feed speed at the
end of the welding job so that the crater
can be filled using a lower power level.
Crater fill duration, wire feed speed and
voltage are preset by the user. The crater
fill start level cannot be smaller than the
crater fill end level.
When the 4T timer is set to ON, releasing
the trigger during crater fill does not end
welding.
Touch Sense Ignition (TSI) delivers min-
imum spatter and stabilizes the arc imme-
diately after ignition.
The WiseFusion feature enables adaptive
arc length control, which keeps the arc
optimally short and focused. For more
information, refer to "WiseFusion feature"
on page 50.
Description
The pulse current relative to the base cur-
rent in pulse and double pulse welding.
These adjust the double pulse frequency
and time percentage.
The pulse ratio adjusts the first pulse
level. When the pulse ratio is set at 35 %,
the ratio of the second pulse level is 65 %.
Note : The wire feed speed and voltage
fine tuning are adjusted in the main view.
This adjusts the MAX Position frequency.
Master M 353, 355
1921960 / 2307

Advertisement

Table of Contents
loading

This manual is also suitable for:

Master m 355

Table of Contents