Status parameters (from welding system to robot)
Byte
0
1
2
© Kemppi
UINT16
UINT16
UINT16
UINT16
UINT16
UINT16
Bit/Type
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
(Not in use)
(Not in use)
(Not in use)
(Not in use)
(Not in use)
(Not in use)
Status parameter
ArcOn
CycleOn
WeldingSystemReady
PowerSourceReady
Watchdog
Error
Warning
(Not in use)
(Not in use)
GasFlowOK
WaterFlowOK
(Not in use)
TouchSensed
CollisionDetected
(Not in use)
(Not in use)
(Not in use)
(Not in use)
(Not in use)
(Not in use)
(Not in use)
(Not in use)