2. INSTALLATION

Do not connect the equipment to the mains before the installation is complete.
Do not modify the welding equipment in any way, except for the changes and adjustments covered in the man-
ufacturer's instructions.
Do not attempt to move or hang the equipment mechanically (e.g. with a hoist) from the handle on the power
source unit. The handles are for manual moving only.
When installing the full set of equipment stacked as a tower – water cooler at the bottom, power source in the
middle and RCM at the top – always install and secure the equipment onto a Kemppi stand compatible with AX MIG
Welder or secure the equipment to other adequate support on site.
Place the machine on a horizontal, stable and clean ground. Protect the machine from rain and direct sunshine.
Check that there is enough space for cooling air circulation in the machine vicinity.
Before installation
Make sure to acknowledge and follow the local and national requirements regarding installation and use of high
voltage units.
Check the contents of the packages and make sure the parts are not damaged.
Before you install the power source on site, see the requirements for the mains cable type and fuse rating.
Distribution network
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the
public low-voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in
those locations, due to conducted as well as radiated radio-frequency disturbances.
X5 power source 400 A: Provided that the short circuit power of public low voltage system at the point of common
coupling is higher than 5.8 MVA, this equipment is compliant with IEC 61000-3-11:2017 and IEC 61000-3-12:2011
and can be connected to public low voltage systems. It is the responsibility of the installer or user of the equipment
to ensure, by consultation with the distribution network operator if necessary, that the system impedance complies
with the impedance restrictions.
X5 power source 400 A Pulse and Pulse+ : Provided that the short circuit power of public low voltage system at the
point of common coupling is higher than 6.3 MVA, this equipment is compliant with IEC 61000-3-11:2017 and IEC
61000-3-12:2011 and can be connected to public low voltage systems. It is the responsibility of the installer or user of
the equipment to ensure, by consultation with the distribution network operator if necessary, that the system imped-
ance complies with the impedance restrictions.
X5 power source 500 A: Provided that the short circuit power of public low voltage system at the point of common
coupling is higher than 6.4 MVA, this equipment is compliant with IEC 61000-3-11:2017 and IEC 61000-3-12:2011
and can be connected to public low voltage systems. It is the responsibility of the installer or user of the equipment
to ensure, by consultation with the distribution network operator if necessary, that the system impedance complies
with the impedance restrictions.
X5 power source 500 A Pulse and Pulse+: Provided that the short circuit power of public low voltage system at the
point of common coupling is higher than 6.7 MVA, this equipment is compliant with IEC 61000-3-11:2017 and IEC
61000-3-12:2011 and can be connected to public low voltage systems. It is the responsibility of the installer or user of
the equipment to ensure, by consultation with the distribution network operator if necessary, that the system imped-
ance complies with the impedance restrictions.
© Kemppi
21