Table of Contents

Advertisement

MAX Speed parameters
The parameters listed here are available for adjustment with the MAX Speed process.
Parameter
MAX Speed frequency
MAX Position parameters
The parameters listed here are available for adjustment with the MAX Position process.
Parameter
MAX Position frequency
Pulse current
Plate thickness
Tip: For more information on the additional welding features and functions, refer to "Additional guidance to
functions and features" on page 137.

3.2.6 WPS

The use of digital WPS (Welding Procedure Specification, dWPS) and WeldEye cloud service require a valid Kemppi WeldEye
subscription with the Welding Procedures module. The AX MIG Welder equipment includes a link to a free trial registration –
featuring also a free trial option for WeldEye ArcVision. For more information on WeldEye, refer to
your Kemppi representative.
Trial registration
AX MIG Welder comes preinstalled with a trial license for the WeldEye Welding Procedures module. The trial license can
be activated by following these steps:
© Kemppi
Parameter value
100 ... 800 Hz, AUTO, step 10
Parameter value
-0.5 ... +0.5 Hz, step 0.1
Default = 0
-10 ... 15 %, step 1
Default = 0
3.0 ... 12.0 mm
112
Operating manual - EN
Description
MAX Speed frequency setting.
Description
MAX Position frequency fine tuning.
MAX Position pulse current adjustment.
MAX Position plate thickness setting.
weldeye.com
or contact
AX MIG Welder
1921900 / 2318

Advertisement