5.4 Cooling unit
X5 Cooler 1400
Feature
Supply voltage
Maximum supply current
Cooling power
Recommended coolant
Maximum coolant pressure
Tank volume
Operating temperature
range
Storage temperature range
EMC class
Degree of protection
Package external dimensions
Weight
Standards
© Kemppi
@ 380...460 V
@ 1 L/min
With recommended coolant
When mounted
L x W x H
Without accessories
169
U
1
I
1max
AX MIG Welder
Operating manual - EN
Value
380...460 V +/- 10 %
0.7 A
1.4 kW
MGP 4456 (Kemppi mixture)
0.4 MPa
3 l
-10...+40 °C
-40...+60 °C
A
IP23S
790 x 300 x 320 mm
15 kg
IEC 60974-2, -10
1921900 / 2318