Memory Channel Change Timing; Wire Inch Timing - Kemppi AX MIG Welder Operating Manual

Table of Contents

Advertisement

2.28.2 Memory channel change timing

Changing a memory channel during welding is not recommended when changing from one process to another (e.g.
from 1-MIG to Pulse).
Description
Total time

2.28.3 Wire inch timing

This section describes the timing for the wire inch forward and wire inch backward functions when controlled by the
robot.
Wire inch startup timing
Item
Description
1
Wire feeding OFF
2
Startup
3
Wire feeding, slow phase
4
Wire feeding, fast phase
Wire inch stop timing
Item
Description
1
Wire feeding ON
2
Stop
Wire feeding deceleration
3
Wire feeding OFF
4
© Kemppi
Min
Typical
0.5
1
Min
-
20
3
-
Min
-
-
-
-
89
Max
2.5
Typical
Max
-
-
40
100
3
3
-
-
Typical
Max
-
-
40
-
30
-
-
-
AX MIG Welder
Operating manual - EN
Units
s
Units
-
ms
s
-
Units
-
ms
ms
-
1921900 / 2318

Advertisement

Table of Contents
loading

Table of Contents