2
Touch sensor off timing
Symbol
1
2
3
2.28.5 Stop switch response timing
Symbol
A
B
1
2
© Kemppi
Fast status output
Description
Touch sensor ON
Control response time
Touch sensor OFF
Description
Stop switch response time
Welding system stop time
Welding system operating
Welding system stopped
-
-
Min
Typical
-
-
20
35
-
-
Min
Typical
-
25
-
40
-
-
-
-
91
AX MIG Welder
Operating manual - EN
-
-
Max
Units
-
-
60
ms
-
-
Max
Units
-
ms
-
ms
-
-
-
-
1921900 / 2318