R-IN32M3-EC User's Manual
⚫ Link Fail Inhibit Timer
The link fail inhibit timer is defined as the waiting time from signal loss or becomes abnormal to link down and it is
usually 850 ms.
These three timers can be set by setting bits 8 to 5 in register 18 (PHY_MODE[3:0] bits). When PHY_MODE[3] is 0,
the value of PHY_MODE[1:0] cannot be reflected. Set PHY_MODE[3] to 1 when using this function.
PHY_MODE[3]
PHY_MODE[1:0]
0
1
1
1
1
R18UZ0003EJ0501
Jan. 12, 2021
Break Link Timer
XX
1250 ms
00
80 ms
01
120 ms
10
240 ms
11
1250 ms
7. Ethernet PHY Function
Auto-Negotiation
Link Fail Inhibit Timer
Wait Timer
850 ms
35 ms
50 ms
100 ms
850 ms
850 ms
50 ms
75 ms
150 ms
850 ms