Renesas R-IN32M3 Series User Manual page 105

Hide thumbs Also See for R-IN32M3 Series:
Table of Contents

Advertisement

R-IN32M3-EC User's Manual
6.13.4
AL Event Request Register (AL_EVENT_REQ)
AL_EVENT_REQ indicates events of AL event request (PDI interrupt).
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
AL_EVENT_
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
REQ
0
0
0
0
0
ECAT
0
0
0
0
0
PDI
Bit Position
Bit Name
15
SMINT7
14
SMINT6
13
SMINT5
12
SMINT4
11
SMINT3
10
SMINT2
9
SMINT1
8
SMINT0
6
WDPD
4
SYNCACT
DCSYNC1STA State of DC SYNC1
3
DCSYNC0STA State of DC SYNC0
2
R18UZ0003EJ0501
Jan. 12, 2021
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
SyncManager 7 Interrupt (bit 0 or 1 in SyncManager status register (0x083D))
0: No SyncManager 7 interrupt
1: SyncManager 7 interrupt pending
SyncManager 6 Interrupt (bit 0 or 1 in SyncManager status register (0x0835))
0: No SyncManager 6 interrupt
1: SyncManager 6 interrupt pending
SyncManager 5 Interrupt (bit 0 or 1 in SyncManager status register (0x082D))
0: No SyncManager 5 interrupt
1: SyncManager 5 interrupt pending
SyncManager 4 Interrupt (bit 0 or 1 in SyncManager status register (0x0825))
0: No SyncManager 4 interrupt
1: SyncManager 4 interrupt pending
SyncManager 3 Interrupt (bit 0 or 1 in SyncManager status register (0x081D))
0: No SyncManager 3 interrupt
1: SyncManager 3 interrupt pending
SyncManager 2 Interrupt (bit 0 or 1 in SyncManager status register (0x0815))
0: No SyncManager 2 interrupt
1: SyncManager 2 interrupt pending
SyncManager 1 Interrupt (bit 0 or 1 in SyncManager status register (0x080D))
0: No SyncManager 1 interrupt
1: SyncManager 1 interrupt pending
SyncManager 0 Interrupt (bit 0 or 1 in SyncManager status register (0x0805))
0: No SyncManager 0 interrupt
1: SyncManager 0 interrupt pending
Watchdog Process Data
0: Has not expired
1: Has expired
This bit is cleared by reading the watchdog status process data register (WDS_DATA:
0x0440) from PDI.
SyncManager Activation Register (SMm.ACT: 0x0806+8H*m) Changed
0: No change in any SyncManager
1: At least one SyncManager changed
This bit is cleared by reading the SyncManager activation register (SMm.ACT) from PDI.
This bit is cleared by reading the SYNC1 status register (DC_SYNC_STAT1: 0x098F)
from PDI.
This bit is cleared by reading the SYNC0 status register (DC_SYNC_STAT0: 0x098E)
from PDI.
6. EtherCAT Slave Controller Function
0
0
R
R
R
R
R
R
R
0
0
R
R
R
R
R
R
R
Description
8
7
6
5
4
3
2
1
0
0
0
0
R
R
R
R
R
R
R
R
0
R
R
R
R
R
R
R
R
Page 92 of 224
Address
400E 0220H
Initial Value
0000 0000H