CHAPTER 10: CLAMP UNIT
3. Removing the Clamp Sensors A & B
(1) Switch off the machine power, remove the rear cover, and swing open the PCB bracket of the power supply
PCB and mechanical control PCB.
(2) Detach the clamp unit.
(3) Unplug the reusable band (1pc) from the clamp unit.
(4) Remove a screw (M3x6: 1pc) and detach the clamp sensor plate with the two sensors attached.
(5) Unplug the connectors and unhook and remove each sensor from the clamp sensor plate.
DANKA AUSTRALIA PTY. LTD.
Clamp sensor-A
Clamp sensor-B
[ 10 - 8 ] - Rev. 0.2
Reusable band
Clamp sensor plate
1014
RZ9 Series