CHAPTER 17: TEST MODE
Panel Contrast Adjustment
Description
1231
Setting
Panel Back-light Adjustment
Description
1232
Setting
TPH master-making horizontal position adjustment
Description
1233
Setting
TPH resistance input
Description
Setting
1234
Setting
DANKA AUSTRALIA PTY. LTD.
Adjusts the contrast of the operation panel display.
Range :
-120 to +120
Unit :
1
Default :
0
Adjusts the back-light of the operation panel display.
Range :
50 to 115
Unit :
1
Default :
85
Sets the TPH master-making position to the center
Range :
-30 to +30 (-30mm to +30mm)
(+ values bring the master-making image to the left)
Unit :
1 (0.1mm)
Default :
0 (0mm)
Sets TPH resistance.
Range :
1200 to 2300
1200 to 1900
Unit :
1 (1 ohm)
Default :
1200 (1200 ohm)
Range :
1200 to 5920
Unit :
1 (1 ohm)
Default :
1200 (1200 ohm)
[ 17 - 28 ] - Rev. 0.2
(1200 ohm to 2300 ohm) : 600dpi
(1200 ohm to 1900 ohm) : 300dpi
(1200 ohm to 5920 ohm)
x o