CHAPTER 17: TEST MODE
Paper-feed-clutch ON angle (Adjustment 4)
Description
0770
Setting
Paper-feed-clutch OFF angle (Adjustment 4)
Description
0771
Setting
Elevator upper-limit position selection (for user-mode paper finish type 4)
Description
0772
Setting
Paper-feed-clutch ON angle (Adjustment 5)
Description
0773
Setting
Paper-feed-clutch OFF angle (Adjustment 5)
Description
0774
Setting
Elevator upper-limit position selection (for user-mode paper finish type 5)
Description
0775
Setting
Paper-ejection wing position compensation
Description
0779
Setting(RZ5)
Setting(RZ9)
Paper-ejection wing fixed-position selection
Description
0780
Setting
DANKA AUSTRALIA PTY. LTD.
Adjusts the drum angle timing for the paper-feed-clutch ON
(For user-mode paper finish type 4) This value is added to
the adjustment value of Test Mode No.741.
Range : -200 to +200 (-20.0° to +20.0°)
(+ values delay ON timing )
Unit :
5 (0.5°)
Default : 0 (0°)
Adjusts the drum angle timing for the paper-feed-clutch OFF
(For user-mode paper finish type 4)
Range : -200 to +200 (-20.0° to +20.0°)
(+ values delay ON timing )
Unit :
5 (0.5°)
Default : 0 (0°)
Selects the paper-feed-tray upper-limit position (For user-
mode paper finish type 4)
0 : High (paper feed pressure is higher)
1 : Middle (paper feed pressure is middle) <default>
2 : Low (paper feed pressure is lower)
Adjusts the drum angle timing for the paper-feed-clutch ON
(For user-mode paper finish type 5)
Range : -200 to +200 (-20.0° to +20.0°)
(+ values delay ON timing )
Unit :
5 (0.5°)
Default : 0 (0°)
Adjusts the drum angle timing for the paper-feed-clutch OFF
(For user-mode paper finish type 5)
Range : -200 to +200 (-20.0° to +20.0°)
(+ values delay ON timing )
Unit :
5 (0.5°)
Default : 0 (0°)
Selects the paper-feed-tray upper-limit position (For user-
mode paper finish type 5)
0 : High (paper feed pressure is higher)
1 : Middle (paper feed pressure is middle) <default>
2 : Low (paper feed pressure is lower)
Compensates the amount of the paper-ejection wing
movement.
Range :
-20 to +20 (-20 pulses to +20 pulses)
Unit :
1 (1 pulse)
Default :
0 (0 pulse)
Range :
-20 to +20 (-20 pulses to +20 pulses)
Unit :
1 (1 pulse)
Default :
9 (9 pulse)
Fixes the paper-ejection wing position when custom position
is selected by the operator. The adjusted position also
applies to test mode No.0704.
Range :
0 to 2150 (0 pulse to 2150 pulses)
Unit :
1 (1 pulse)
Default :
1434 (1434 pulses)