CHAPTER 12: FB ORIGINAL SCANNING SECTION
2. Removing the Stage Glass
(1) Switch off the machine power and remove the following covers.
-
Scanner cover;paper feed
-
Scanner cover;paper ejection
(2) Remove two shoulder screws and detach the original stopper.
(3) Detach the plate springs F & R by removing screws (M3x6: 2pcs each).
(4) Lift and remove the stage glass.
Original Stopper
< Stage-glass installation procedure >
(1) Put the stage glass on the scanner unit.
(2) Install the original stopper.
(3) Push and slide the stage glass against the original stopper.
(4) Install the plate springs F & R, pushing tightly against the stage glass, and secure with screws.
(5) Reinstall the covers.
DANKA AUSTRALIA PTY. LTD.
Stage Glass
1207
Scanner Unit
Stage Glass
[ 12 - 8 ] - Rev. 0.2
Plate spring-R
Plate spring-F
1208
Scanner Unit
Plate spring-F
1209