Download Print this page

Adjustment; Squeegee Gap Adjustment - Riso RZ9 Series Technical Manual

Hide thumbs Also See for RZ9 Series:

Advertisement

CHAPTER 9: PRINT DRUM SECTION

Adjustment

1. Squeegee Gap Adjustment

Checks and adjustment
(1) Remove the print drum from the machine and detach following components off the print drum.
-
Screen assembly
-
Drum body
-
Drum cover
(2) Detach the drum handle and drum handle lever. (Refer to the photograph below for the location).
(3) Clean out the ink inside the squeegee unit.
(4) Use a feeler gauge to check the gap between the squeegee roller and doctor roller.
* The gap should be 0.08mm plus/minus 0.02mm .
(5) If the gap is out of the specified range, loosen the securing screw on the squeegee-gap adjustment plate.
(6) Insert a flat-head screw driver in the groove on the squeegee-gap adjustment plate and move the plate to
adjust the squeegee gap.
(7) Tighten the securing screw on the squeegee-gap adjustment plate to end the adjustment.
- Refer to the next page for the photograph of the rear side.
Squeegee-gap adjustment plate
Securing screw on the Squeegee-gap adjustment plate.
DANKA AUSTRALIA PTY. LTD.
Drum handle
Drum handle
lever (inside)
0945
0965
[ 9 - 28 ] - Rev. 0.2
< FRONT >
Squeegee-gap adjustment plate
Narrower
Wider
0964
0966