CHAPTER 11: MASTER REMOVAL SECTION
5. Removing the Master Removal Sensor & Master Sensor
(1) Switch off the machine power and detach the master removal unit from the machine.
Removing the master sensor
(2) Disconnect the sensor connector, remove a screw (M3x6: 1pc), and detach the master sensor together
with the sensor bracket.
Removing the master sensor
(2) Disconnect the sensor connector, remove a screw (M3x6: 1pc) by inserting a screwdriver through a hole on
the master disposal housing, and detach the master sensor.
Master sensor
DANKA AUSTRALIA PTY. LTD.
Master disposal housing
1118
< Master Removal Unit >
[ 11 - 12 ] - Rev. 0.2
Master removal sensor
1119
1120