Download Print this page

Riso RZ9 Series Technical Manual page 414

Hide thumbs Also See for RZ9 Series:

Advertisement

CHAPTER 16: PANEL MESSAGE
Error Type
T98 [Hardware error]
T98-xxx
!!System Error!!
Description
Press Reset Key
If Recovery has Failed, Call Service
To reset
Turn power OFF and ON.
display
Error Point
075
Communication error between SH PCB and MCTL PCB (11) - on SH PCB side.
076
Communication error between SH PCB and MCTL PCB (12) - on SH PCB side.
077
Communication error between SH PCB and MCTL PCB (13) - on SH PCB side.
078
Communication error between SH PCB and MCTL PCB (14) - on SH PCB side.
079
Communication error between SH PCB and MCTL PCB (15) - on SH PCB side.
080
Communication error between SH PCB and MCTL PCB (16) - on SH PCB side.
081
Communication error between SH PCB and MCTL PCB (17) - on SH PCB side.
082
Communication error between SH PCB and MCTL PCB (18) - on SH PCB side.
083
Communication error between SH PCB and MCTL PCB (19) - on SH PCB side.
084
Communication error between SH PCB and MCTL PCB (20) - on SH PCB side.
098
Machine serial number information on EEPROM does not match with that of FRAM.
119
Defective image PCB (memory check error on the image processing IC).
120
Timeout on the scanner serial communication.
129
Defective scanner gate array PCB (memory check error on the gate array).
245
Timeout error on master transfer during master-making (related to Write pulse motor).
246
Timeout error on master transfer during master-making (related to Load pulse motor).
The light emittance from the Paper sensor (send) exceeded the maximum allowance
422
during the Automatic Multiple Paper Feed Adjustment [paper sensor sensitivity
adjustment] by Test Mode No.705.
The light emittance from the Paper sensor (send) exceeded the minimum allowance
423
during the Automatic Multiple Paper Feed Adjustment [paper sensor sensitivity
adjustment] by Test Mode No.705.
921
The USB controler chip is not responding when PC and printer is connected by USB cable. x
934
Communication error between MCTL PCB and RF PCB. (on FR PCB side)
935
Communication error between MCTL PCB and RF PCB. (on MCTL PCB side)
937
Undefined serial number.
938
FRAM version down.
947
24V-A does not go ON. (Possible broken Fuse for 24V-A area).
948
24V-A does not go ON. (Possible broken Fuse for 24V-B area).
949
24V-A does not go OFF.
950
24V-B does not go OFF.
952
SH3M2 PCB flash memory check-sum error.
953
Unsuccessful writing on the SH3M2 PCB flash memory.
960
Unsuccessful readout from the SH3M2 PCB flash memory.
961
SH3M2 PCB flash memory unused.
978
Incorrect power ON command from MCTL PCB when machine power turned ON.
979
Abnormal flash memory setting on the SH3M2 PCB.
983
24V-C does not go ON. (Possible broken Fuse for 24V-C area).
984
24V-C does not go OFF.
Error Type
T99 [Software error]
T99-xxx
!!System Error!!
Description
Press Reset Key
If Recovery has Failed, Call Service
To reset
Turn power OFF and ON.
display
Error Point
181
Timeout on Image processing time.
982
Wrong loader.
DANKA AUSTRALIA PTY. LTD.
Error Conditions
Error Conditions
[ 16 - 18 ] - Rev. 0.2
3
5
9
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
x
x O
x
x O
x O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
x O O
x O O
x O O
x O O
x
x O
x
x O
3
5
9
x
x O
x O
x
RZ9 Series