5. Removing the Scanner Lamp

(1) Run Test Mode No.287 (scanner lamp replace positioning) and switch off the machine power.
(2) Remove the stage glass.
(3) Remove screws( M3x6: 2pcs) and detach the inverter cover.
(4) Unhook the wire harness to the scanner lamp from the cord clamps (2 locations), and disconnect the
connector from the inverter.
(5) By lifting the clear plastic sheet on the cutout section of the scanner unit, remove screws (M3x6: 1pc each)
from the both sides, and detach the scanner lamp.
Cutout section
Connector
DANKA AUSTRALIA PTY. LTD.
Scanner lamp
Cord clamps
Wire harness