Figure 6-5:Xv-Board Ai Channel Setting Page - ICP DAS USA WISE-2841M Series User Manual

Hide thumbs Also See for WISE-2841M Series:
Table of Contents

Advertisement

ICP DAS WISE User Manual
After all settings of the channels are completed, click "OK" button to
return to XV-Board Setting page.
6.1.3 XV-Board AI Channel Settings
The XV-Board AI Channel Setting page is shown as follow (using
XV310 as an example):
The settings are as follow:
 Nickname: For user to define nicknames for each I/O channel,
 Type: Select the input signal type of the AI channel from the
 Scale: In the "Scale" field, AI channel raw data can be set to
http://wise.icpdas.com
on the XV-Board will be copied to the DO channel. For
example, when the "DI Status Mapping" is enabled on DO0,
when the DI0 status is ON, DO0 will set to be ON, and when
the DI0 status is OFF, DO0 will set to be OFF as well.
Figure 6-5:XV-Board AI Channel Setting Page
these nicknames will be displayed on the "Channel Status" and
"Rule Setting" pages.
dropdown list.
operate with linear proportion between "Minimum" and
"Maximum"
values.
already-adjusted value in the evaluation operation, and the AI
value retrieved from the "Channel Status" page or Modbus Table
via WISE would be the adjusted value. The default value for
Maximum and Minimum is 0, it means the Scale function is
disabled.
The
IF
Condition
will
use
this
60

Advertisement

Table of Contents
loading