Otto Bock Meridium 1B1-2 Series Instructions For Use Manual page 53

Hide thumbs Also See for Meridium 1B1-2 Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 43
CAUTION
Using prosthetic foot without footshell
Falling due to slipping when walking on smooth floor surfaces (tiles).
► Do not use the prosthetic foot without the accompanying footshell.
CAUTION
Using prosthetic foot with a damaged foot shell
>
Falling due to unexpected product behaviour as the result of malfunction.
>
Falling due to breakage of load-bearing components.
► Do not use the prosthetic foot when the foot shell is damaged. Replace damaged foot shells immediately,
before using the product again.
4.9 Notes on the safety modes
CAUTION
Using the product in safety mode
Falling due to unexpected product behaviour because of changed damping behaviour.
► The warnings/error signals (see page 77) have to be observed.
CAUTION
Safety mode cannot be activated due to malfunction caused by water penetration or mechanical damage
Falling due to unexpected product behaviour because of changed damping behaviour.
► Using the product when it is defective is prohibited.
► The product must be inspected by an authorised Ottobock Service Centre.
CAUTION
Safety mode cannot be deactivated
Falling due to unexpected product behaviour because of changed damping behaviour.
► If safety mode cannot be deactivated by recharging the battery, a permanent error has occurred.
► Using the product when it is defective is prohibited.
► The product must be inspected by an authorised Ottobock Service Centre.
CAUTION
Safety signal occurs (ongoing vibration)
Falling due to unexpected product behaviour because of changed damping behaviour.
► The warnings/error signals (see page 77) have to be observed.
► After the safety signal has been emitted, further use of the product is prohibited.
► The product must be inspected by an authorised Ottobock Service Centre.
4.10 Information on the use of a mobile device with the cockpit app
CAUTION
Improper use of the mobile device
Falling due to altered damping behaviour as a result of unexpected switching into a MyMode.
► Use the instructions for use (user) to instruct the patient on the proper handling of the mobile device with the
Cockpit app.
CAUTION
Independently applied changes or modifications made to the mobile device
Falling due to altered damping behaviour as a result of unexpected switching to a MyMode.
► Do not make any independent changes to the hardware of the mobile device on which the app is installed.
► Do not make any independent changes to the software/firmware of the mobile device that are not included in
the update function of the software/firmware.
1B1-2=* Meridium
Safety
53

Advertisement

Table of Contents
loading

Table of Contents