Cabletron Systems Netlink FRX8000 User Manual page 203

Fully integrated lan/wan enterprise switch
Hide thumbs Also See for Netlink FRX8000:
Table of Contents

Advertisement

Blocked Port Flag
X.3 Line Speed Code
Profile Name
Login Required
Banner Name
Parity:
Configuring Async Pads
LICs are shown in parentheses:
= RS-232 (RS-232)
3
= RS-449 (RS-422)
6
causes the port to be enabled (
that state until this parameter is changed (and sent to the node) or an on-line enable/
disable is performed. (See
specifies the data transmission rate in bits per second. Select the speed that corre-
sponds (as closely as possible) to the configuration of the device connected to the port.
Codes are as follows.
= 110
= 134.5
0
1
= 75
= 1500
5
6
= 50
10
11
= 19.2K
15
16
The maximum speed for an RS-232 physical interface on an N7400 or
7500 is 19.2K.
Autobaud causes the FRX8000 to read the line speed of the first trans-
mission from the async device, then set that speed at the port (up to a
maximum of 57.6K bps). To specify
Speed Code
accepted.) Also, autobaud will not work if the actual line speed of the async
device is
38.4K bps
is an async PAD profile (described on page 13-2) that will be in effect on this port until
the async subscriber logs into the PAD (described on
profile in the
Async PAD Login record
determines whether or not async PAD subscribers will be required to log in before
connecting with this port. If
(specified in the Subscriber record) and password (specified in the Async PAD Login
record) to connect.
identifies the PAD "banner," a string of characters sent to the async PAD port for
display on the user device when a subscriber becomes connected at level 1. It is
usually a message telling the subscriber he is now connected. The banner is defined in
a separate operation, described on
= None
= Auto-detect
0
1
FRX8000 8000 supports 8 data bits with no parity checking, or 7 data bits
with even or odd parity checking. It also supports 7 data bits with auto-
detect parity checking if
21 is configured to check parity.
= V.25Bis_Dial (RS-232)
4
= RS-530 (RS-422)
7
) or disabled (
N
"Disabling and Enabling Ports"
= 300
2
= 1800
7
= 75/1200
= 2400
12
= 38.4K
= 57.6K
17
prompt to accept the default. (Do not enter
. If this is the speed, select value
(described on page 13-8) takes effect.
, the async device operator must enter a subscriber ID
Y
page
13-10.
= Even
2
X.3 Line Speed
= V.35 (V.35)
5
= X.21 (RS-422)
8
) at node IPL. The port will remain in
Y
on page 18-1.)
= 1200
3
= 200
8
= 4800
13
= Autobaud
255
, press
Autobaud
[Enter]
255
.
16
page
A-1), at which time the
= Odd
3
is set to
and PAD profile
Autobaud
= 600
4
= 100
9
= 9600
14
at the
X.3 Line
; it will not be
13-13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Netlink FRX8000 and is the answer not in the manual?

Questions and answers

Table of Contents