Cabletron Systems Netlink FRX8000 User Manual page 340

Fully integrated lan/wan enterprise switch
Hide thumbs Also See for Netlink FRX8000:
Table of Contents

Advertisement

21-18
Meaning:
Self-explanatory. The values for parameters
Network Defaults file are changed to the values shown.
113.
Alternate Node changed to "n" on Node "n"
Severity:
4
Meaning:
The Alternate NMP Node has been changed to the first "n" in the
Node record for the second "n."
114.
PVC from (Subscriber ID) - (LCN) to (Subscriber ID) - (LCN) disconnected
Severity:
4
Meaning:
Self-explanatory.
115.
PVC connection failure from (Subscriber ID) - (LCN) to (Subscriber ID) - (LCN)
Severity:
3
Meaning:
The PVC could not be connected for one of these reasons:
If "
"=
n
The PVC request from the local
Either the channel requested was
LP/port was invalid because one or both were not operational.
If "
" =
n
The PVC already exists at the local (
same LP/port and LCN as those requested. The existing
PVC must be removed before it can be recreated.
Action:
Self-explanatory, as described in the meaning.
116.
PVC primary setup failure from (Subscriber ID) - (LCN) to (Subscriber ID) -(LCN)
Severity:
3
Meaning:
There is a problem with the connection from the first subscriber that
was configured in a particular PVC Connection record. Usually this
means that the subscriber's port is not configured, or that the LP is
either not configured correctly or is not installed.
Action:
Check the configuration records for the LP and port specified in the
Subscriber record. If these are all right, check the hardware config-
uration.
117.
PVC secondary setup failure from (Subscriber ID) - (LCN) to (Subscriber ID) (LCN)
Severity:
3
Meaning:
There is a problem with the connection from the second subscriber
that was configured in a particular PVC Connection record. Usually
this means that the subscriber's port is not configured, or that the LP
is either not configured correctly or is not installed.
Action:
Check the configuration records for the LP and port specified in
the Subscriber record. If these are all right, check the hardware
configuration.
or
:
1
11
or
:
2
12
in the node's
"x"–"y"
) or remote (
) end was bad.
(1
11
or the specified
0
) or remote (
) end with the
2
12
FRX8000 3.0 User Guide, Rev 02