Alarms
– during the link layer–to–PL message Main routine
b714
(pl_lldata()), the facility was LPRSDM (Reset Slowdown Mode).
– during the link layer–to–PL message Main routine
b715
(pl_lldata()), the facility was LPSSDM (Set Slowdown Mode) and
the VC ID was invalid.
– during the link layer–to–PL message Main routine
b716
(pl_lldata()), the facility was LPRSET (Received SNRM for FRMR
reset by secondary; will send QSNRM to RSAP) the VC ID was
invalid.
– during the link layer–to–PL message Main routine
b717
(pl_lldata()) if the VC ID was invalid.
– during the PL Main routine, the VC ID was invalid; this is
b718
followed by another error containing the message VC ID.
– the link level data–to–level 3 routine (spfldtl3()) was called
ba01
and the data was lost.
– the Log Error Message routine (x_logerr()) was called from
ba02
the NPAD Finite State Machine module.
– the Trap Action routine (xllc_trap()) was called from the
ba03
NPAD Finite State Machine module.
– the spxllc_main() routine (called to receive all XPAD
bb01
messages) was called with an invalid port type.
– the spxllc_main() routine (called to receive all XPAD
bb02
messages) was called with a message type of NETFRM (received
frame from the driver) and the frame was more than the maximum
data size supported (12data_size).
– the spxllc_main() routine (called to receive all XPAD
bb03
messages) was called with an Unknown Message Type.
– the spll_ctlmsg() routine was called with an Unknown
bb04
Facility.
– the spll_pktmsg() routine (received message from the packet
bb07
layer) was called with an Unknown Facility.
– the spll_linkch() routine was called with an Unknown
bb08
Level 1 State.
– the SPLLC Main routine (spllcmr()) received a message with
bc01
a bad port type.
– the Acknowledge Queue exceeded the window. (Generated
bd01
from the Common Flow Chart Action routine of the SDLC
Secondary module (sps_ac91()).
– the Trap Action routine (sllc_trap()) of the SDLC Secondary
bd02
module was called.
– the SDLC Main routine received a message of type
be01
WACKOUT (no piggyback acknowledged)
– the SNA exchange received an unknown message. This error
be04
should be immediately followed by another event 147, containing
what is probably the correct error code.
21-25