Alarms
Action:
Check the configuration records for the port, and correct the DLCI.
372.
Node "n" LP "n" Port "n" DLCI "n" PVC does not exist
Severity:
3
Meaning:
Self-explanatory.
Action:
Create a PVC Connection record.
373.
FR LP "n" Port "n" DLCI "n" frame discarded–congestion
Severity:
3
Meaning:
Self-explanatory.
Action:
The frame must be re-sent.
374.
Node "n" LP "n" Port "n" DLCI "n" frame relay logical trunk configured on a
DCE port
Severity:
3
Meaning:
Self-explanatory; frame relay trunks can only exist on DTE ports.
Action:
Configure the trunk on a DTE port.
375.
Node "n" LP "n" Port "n" DLCI "n" frame relay PVC deleted
Severity:
4
Meaning:
Self-explanatory.
376.
Node "n" LP "n" Port "n" DLCI "n" Frame Relay PVC connected to Node "n"
LP "n" Port "n" DLCI "n"
Severity:
3
Meaning:
Self-explanatory.
377.
LP "n" Interface board "n" is installed but not configured
Severity:
3
Meaning:
The software has discovered the presence of an RLP Line Interface
Card that has no records in the Port file.
Action:
Create records for the ports on the interface card.
378.
LP"n" Interface board "n" is Configured, but not Installed
Severity:
1
Meaning:
The software has discovered Port records for an RLP Line Interface
Card that is not present in the node.
Action:
Install the interface card, or delete the records.
379.
LP "n's" Interface board "n" configuration mismatch – installed type "n"
Severity:
2
Meaning:
The Physical Interface specified in the Port record(s) for RLP Line
Interface Interface card do not match the hardware.
21-45
Need help?
Do you have a question about the Netlink FRX8000 and is the answer not in the manual?