Mask Link Alarms
Link Management
N1 Polling Count
N2 Error Threshold
Monitored Events Count
Link Integrity Timer
Poll Verification Timer
Enable Outgoing Rate Ctrl?
Enable Bandwidth Alloc?
Configuring Frame Relay
determines whether an alarm (see
down. If
Mask Link Alarms
determines whether, and what type of, configurable network management will be
allowed:
= none
0
= LMI (Local Management Interface)
1
= ANSI T1.617 Annex D
2
is the frequency with which the user device will request a Full Status Report, which
shows frame relay PVC status and Keep Alive Sequence information. (Keep Alive
Sequencing is the continuous exchange of sequence numbers between the network and
user device, verifying to each that the link between them is up.)
Each exchange of one enquiry and one message is a cycle, and the number specified
for this parameter is the number of cycles between Full Status Reports.
If this port is configured as logical DCE, status enquiries will be initiated at the remote
end, and the local node will respond with PVC status information. If this port is logical
DTE, status enquiries will be initiated at this node.
is the number of link reliability and/or link management protocol errors that can occur
during the period defined by the
channel or frame relay device is declared inactive.
is used to determine whether a channel or user device is active. After the channel/
device is declared inactive ("
of successful polling cycles specified by the
channel/device active again. The value specified for this parameter should be greater
than or equal to the value specified for
determines the frequency with which the user device will send a Status Enquiry
message to the network, requesting a Keep-Alive Sequence exchange.
determines how long the network will wait between Status Enquiry messages before
recording an error. The value specified for this parameter should be greater than or
equal to the value specified for the
determines whether the rate control parameters (CIR, B
Frame Relay DLCIs
file (see page 8-10) will be enforced. These parameters specify
the traffic load that the port will be committed to handle under normal and bursty (tem-
porarily heavy) conditions.
determines whether
bandwidth allocation
Chapter
21) will be generated if the link goes up or
is
, these alarms will not be generated.
Y
Monitored Events Count
"), the network will wait the number
N2 Error Threshold
Monitored Events Count
.
N2
Link Integrity Timer
(see page 8-2) will be enforced.
(see next entry) before a
, then declare the
.
, B
) configured on the
C
E
8-7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Netlink FRX8000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents