21-26
be05
facility type. This error is immediately followed by another error
indicating the facility type that was received.
be06
Requests) received a message with a Connection ID (cid) greater
than or equal to the maximum number of remote controllers allowed
(MAXRLS). This error is immediately followed by another error
indicating the Connection ID that was received.
be07
Requests) received a message with the facility to Set Slowdown
Mode (PLSSDM) and was unable to do so because the Application
Subfunction Code (sfc) was neither Set Node to RNR (NODERNR)
nor No Buffers Available (NOBUFF).
be08
Requests) received a message with the facility to Reset Slowdown
Mode (PLRSDM) and was unable to do so because the Application
Subfunction Code (sfc) was neither Set Node to RR (NODERR) nor
has Buffers Available (YESBUFF).
be09
Requests) received a message with an Unknown facility. This error
is immediately followed by another error indicating the facility
received.
Action:
If you have any problems resolving this, contact
Technical
167.
LP "n" received invalid big packet configuration
Severity:
3
Meaning:
The LP is an N74/7500 AST card (type 3), its LP record does not
specify
bytes was specified for maximum or default packet size in the Port
record.
Action:
Correct the configuration records.
168.
LP "n" Port "n" received invalid trunk header – Probable Trunk/X.25 mismatch
Severity:
3
Meaning:
Port "n" is not configured as a trunk.
Action:
Check the Port record, and change the configuration if necessary.
169.
Load generator checksum error LCN "n"
Severity:
4
Meaning:
There was a checksum error at the packet level while running the
load generator.
170.
*** OS Error Function "n" Error "n" from "n:n"
Severity:
1
Meaning:
There is a serious problem in the operating system.
– the SDLC routine spsdlc_ctlmsg() received an unknown
– the SDLC routine spsdlc_pktmsg() (process Packet Layer
– the SDLC routine spsdlc_pktmsg() (process Packet Layer
– the SDLC routine spsdlc_pktmsg() (process Packet Layer
– the SDLC routine spsdlc_pktmsg() (process Packet Layer
Support. (See page 21-7.)
Big Packet Supported
Cabletron Systems
, and a packet size greater than
FRX8000 3.0 User Guide, Rev 02
512
Need help?
Do you have a question about the Netlink FRX8000 and is the answer not in the manual?
Questions and answers