Code
Detail
code
E5F3
0001
0002
Name
saddle alignment
error
Detection
The aligning
plate home
position sensor
does not go on
when the
alignment motor
has been driven
for 0.5 sec. (at
time of
initialization,
1.67 sec.)
Alignment motor
(M5S)/aligning
plate home
position sensor
(PI5S)
The aligning
plate home
position sensor
does not go off
when the
alignment motor
has been driven
for 1 sec.
Alignment motor
(M5S)/aligning
plate home
position sensor
(PI5S)
Chapter 15
Remedy
Check the alignment
motor. Check the
alignment home position
sensor. Check the aligning
plate drive mechanism.
Replace the finisher
controller PCB.
15-67