Sub-item
CNT-MCON
Clearing the service counter incremented by the main controller circuit board
The password is cleared when the OK key is pressed.
<Operating procedure>
1) Select this item and press the OK key.
CNT-DCON
Clearing a service counter incremented by the DC controller circuit board
The password is cleared when the OK key is pressed.
This applies to SORT, FIN-STPR, SADDLE, and SDL-STPL under
COPIER>COUNTER>DRBL-2.
<Operating procedure>
1) Select this item and press the OK key.
OPTION
Resetting a service mode (OPTION) to default (values after RAM clearance)
The service mode is reset when the OK key is pressed.
This clears data in the main controller, DC controller, and reader controller.
<Operating procedure>
1) Select COPIER>FUNCTION>MISC-P>P-PRINT to print the contents of the
service mode.
2) Select this item and press the OK key.
MMI
Clearing the following settings in User mode
- Backup data (user-defined values) for copy operations
- Backup data (user-defined values) of common settings
- Various backup data (user-defined values), excluding fax
The settings are cleared when the main power switch is turned OFF and ON.
<Operating procedure>
1) Select this item and press the OK key.
2) Turn the main power switch OFF and ON.
MN-CON
Clearing RAM on the main controller circuit board
The RAM is cleared when the main power switch is turned OFF and ON.
<Operating procedure>
1) Select COPIER>FUNCTION>MISC-P>P-PRINT to print the contents of the
service mode.
2) Select this item and press the OK key.
3) Turn the main power switch OFF and ON.
4) Enter the P-PRINT output data as required.
COPIER > FUNCTION > CLEAR
Description
Chapter 16
Level
1
1
1
1
1
16-65