F-3-17
5) Temporarily tighten the 2 included
screws [1].
6) Remove the screw [2], and detach the
plate [3].
The removed screw will no longer be
used.
F-3-18
7) Open the 3 way unit [1], and tighten the
2 included screws [2].
8) Fully tighten the 2 screws [3] that you
temporarily tightened in step 5).
9) Close the 3 way unit [1].
F-3-19
10) Connect the connector [1] to the host
machine.
11) Route the harness [2] through the cable
clamp [3]; then, fit the 2 reuse bands [2]
into the holes.
F-3-20
Chapter 3