9.3.2.4 Copying Temperature Control
The machine uses this mechanism to control the temperature of the fixing heater to an
optimum level while a recording medium is passing through the fixing film assembly;
specifically,
1.the machine varies the power ratio in relation to the difference between the temperature
detected by the thermistor and the target control temperature.
2.if the temperature detected by the thermistor is higher than the target control temperature
for a specific period of time (0.6 sec), the machine will decrease the power ratio; if lower,
it will increase the power rate.
9.3.2.5 Changing the Fixing Film Control Temperature
When a fixing failure occurs or creases appear, the fixing film control temperature can be
changed in the service mode as shown below.
COPIER> OPTION> BODY> TEMP-CON (to switch the fixing temperature mode for
heavy paper)
COPIER> OPTION> BODY> TEMPCON2 (to switch the fixing temperature mode)
0: OFF (default), 1: -10 deg C, 2: -6 deg C, 3: -3 deg C, 4: +3 deg C, 5: +6 deg C, 6: +10
deg C, 7: 15 deg C
9.3.2.6 Temperature Control in Response to Automatic Double-
Sided Copy
The second side of an automatic double-sided copy requires lower control temperature in
comparison with the first side. For this reason, the control temperature is lowered for the
second side of an automatic double-sided copy so as to prevent adverse effects such as rises
in temperature.
Chapter 9
0006-6584
0007-5452
0007-5453
9-7