Canon imageRUNNER 2270 Service Manual page 612

Hide thumbs Also See for imageRUNNER 2270:
Table of Contents

Advertisement

Chapter 15
 
Code
Cause
0002 The reading of the sub thermistor is
295 deg C or more continuously for
200 msec.
E002
The rise in temperature of the fixing assembly is faulty.
0000 While startup control is under way,
the reading of the main thermistor is
less than 115 deg C continuously for
400 msec 1.3 sec after it has indicated
100 deg C.
While startup control is under way,
the reading of the main thermistor is
less than 150 deg C continuously for
400 msec 1.3 sec after it has indicated
140 deg C.
E003
The fixing temperature is too low after a standby state.
0000 While regular temperature control is
under way, the reading of the main
thermistor is less than 140 deg C
continuously for 400 msec or more.
E007
The rotation of the fixing film is faulty.
0000 While the fixing motor is rotating,
the marker signal is not detected for 6
sec with the reading of the main
thermistor indicating 100 deg C or
more.
E010
The rotation of the main motor is faulty.
0001 Detection is executed every 100
msec after the start of motor rotation;
however, the drive detection signal is
absent for 2 sec.
15-6
Remedy
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Replace the sub thermistor. Replace the
DC controller PCB.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Replace the main thermistor. Replace
the DC controller PCB.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Replace the main thermistor. Replace
the DC controller PCB.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Replace the main thermistor. Replace
the DC controller PCB.
Replace the main motor. Replace the
DC controller PCB.