Siemens Simovert Masterdrives Compendium page 1513

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

Number / Alarm
Cause
A178
- The program number for the main program
(level 0), which was transferred with block
Program number of
search, is different from the selected program
block search forward
number.
not allowed
- No breakpoint is known for the "automatic
block search" function (a program abort has
not yet occurred).
- A different program number is stored as the
breakpoint for the "automatic block search"
function.
Effect:
NC program execution is inhibited.
A179
The subprogram number specified with block
search for level 1 or level 2 does not exist.
Prog.No.of block srch
fwd level 1/2 does not
Effect:
exist
NC program execution is inhibited.
A180
The subprogram number transferred with
block search for level 1 is not the same as the
Prog.no. of block
subprogram number in the NC block.
search forward level 1
<> cmd.
Effect:
NC program execution is inhibited.
A181
The subprogram number transferred with
block search for level 2 is not the same as the
Prog.no. of block
subprogram number in the NC block.
search forward level 2
<> cmd.
Effect:
NC program execution is inhibited.
A183
The block number for the main program (level
0), which was transferred with block search,
Block no. of block
does not exist in the main program.
search fwd l. 0 does
not exist
Effect:
NC program execution is inhibited.
A184
The block number for the main program (level
0), which was transferred with block search,
Block no. of block
does not contain a subprogram call for
search forward is no
subprogram level 1.
UP call
Effect:
NC program execution is inhibited.
A185
The block number for subprogram level 1,
which was transferred with block search, does
Block no. of block
not exist in the subprogram.
search forward does
not exist
Effect:
NC program execution is inhibited.
A186
The block number for subprogram level 1,
which was transferred with block search, does
Block no of block
not contain a subprogram call for subprogram
search fwd lev 1 is no
level 2.
SP call
Effect:
NC program execution is inhibited.
A187
The block number for subprogram level 2,
which was transferred with block search, does
Block no of block
not exist in the subprogram.
search fwd lev 2 does
not exist
Effect:
NC program execution is inhibited.
26
Counter-measure
For the block search function, the selected
program number [PROG_NO] must be
specified as the program number for the main
program.
For the block search function, an existing
program number must be specified as the
subprogram number for level 1 or level 2.
For the block search function, the subprogram
number specified in the NC block must be
specified as the subprogram number for level
1.
For the block search function, the subprogram
number specified in the NC block must be
specified as the subprogram number for level
2.
For the block search function, an existing
block number must be specified as the block
number for the main program.
For the block search function, a block number
with a subprogram call must be specified as
the block number for the main program (level
0) if a block search is to be performed in
subprogram level 1.
For the block search function, a block number
which exists in this subprogram must be
specified as the block number for subprogram
level 1.
For the block search function, a block number
with a subprogram call must be specified as
the block number for subprogram level 1 if a
block search is to be performed in subprogram
level 2.
For the block search function, a block number
which exists in this subprogram must be
specified as the block number for subprogram
level 2.
6SE7087-6QX70 (Version AL)
Compendium Motion Control
03.2010
Siemens AG
SIMOVERT MASTERDRIVES