Siemens Simovert Masterdrives Compendium page 1521

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

Number / Alarm
Cause
A244
Travel table 3 has not been correctly adopted
or has been reset.
Travel table 3 not valid
Consequence:
Travel table 3 cannot be processed.
A245
Travel table 4 has not been correctly adopted
or has been reset.
Travel table 4 not valid
Consequence:
Travel table 4 cannot be processed.
A246
Travel table 5 has not been correctly adopted
or has been reset.
Travel table 5 not valid
Consequence:
Travel table 5 cannot be processed.
A247
Travel table 6 has not been correctly adopted
or has been reset.
Travel table 6 not valid
Consequence:
Travel table 6 cannot be processed.
A248
Travel table 7 has not been correctly adopted
or has been reset.
Travel table 7 not valid
Consequence:
Travel table 7 cannot be processed.
A249
Travel table 8 has not been correctly adopted
or has been reset.
Travel table 8 not valid
Consequence:
Travel table 8 cannot be processed.
34
Table 2
Alarm numbers, causes and their counter-measures
Counter-measure
Adopt travel table 3 again.
Note:
Travel table 3 can only be newly adopted if it is
not selected. When travel table 3 has been
successfully adopted, the alarm message is
automatically canceled.
Adopt travel table 4 again.
Note:
Travel table 4 can only be newly adopted if it is
not selected. When travel table 4 has been
successfully adopted, the alarm message is
automatically canceled.
Adopt travel table 5 again.
Note:
Travel table 5 can only be newly adopted if it is
not selected. When travel table 5 has been
successfully adopted, the alarm message is
automatically canceled.
Adopt travel table 6 again.
Note:
Travel table 6 can only be newly adopted if it is
not selected. When travel table 6 has been
successfully adopted, the alarm message is
automatically canceled.
Adopt travel table 7 again.
Note:
Travel table 7 can only be newly adopted if it is
not selected. When travel table 7 has been
successfully adopted, the alarm message is
automatically canceled.
Adopt travel table 8 again.
Note:
Travel table 8 can only be newly adopted if it is
not selected. When travel table 8 has been
successfully adopted, the alarm message is
automatically canceled.
6SE7087-6QX70 (Version AL)
Compendium Motion Control
03.2010
Siemens AG
SIMOVERT MASTERDRIVES

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents