Connect An Analog Station Or 2-Wire Digital Station - Avaya G700 Installation And Upgrades

Hide thumbs Also See for G700:
Table of Contents

Advertisement

7 Connecting Telephones and Adjunct Systems:
Connect an Analog Station or 2-Wire Digital
Station
This example is typical of the 2-wire digital stations (2420, 64xx, 302D), 2-wire analog stations (2500),
analog Central Office (CO) trunks, Direct Inward Dial (DID) trunks, and external alarms.
1 . Choose a peripheral to connect (such as a 2-wire digital station).
2 . Choose the Media Module to use and its Media Gateway and slot number; for example, MM711
Analog Media Module, Media Gateway 002, Slot V2.
3 . Choose a port circuit on the MM711 Media Module; for example, port 03.
4 . Install cross-connect jumpers to connect the pins from the 2-wire digital station to the
appropriate pins on the MM711 Media Module.
stations.
Table 15. Two-Wire Station Pinout Chart .
Jack Name
BRI-T
ADJUNCT
DSS
(QUEST)
DSS (ISDN)
BRI-A
BRI-U
DCP
ANALOG
HANDSET
5 . Administer using Administrator's Guide for Avaya MultiVantage Software.
Figure 7. 2500-Type Analog Telephone Wiring
Figure notes
1
2500-Type Analog Station
240
1
2
3
+TX
+Vadj
T0
-V
DTX
DRX
GND
TX1
TX2
RX1
-TX
T
2
R
3
Installation and Upgrades for the G700 with an S8300/S8700
Installation and Wiring Telephones and Power Supplies
Table 15
shows a pinout chart for two-wire
4
5
+RX
-RX
GNDVoice
RRVoice +V
TX
RX
TX
RX
TIP
RING
+RX
-RX
28
T.3
03
R.3
2500wire RBP 071996
2
MM711 Analog Media Module,
Position 1V301
555-234-100 — Issue 2 — October 2002
6
7
8
-TX
-V
GND
S0
TTVoice
OKdig -V
+V
-V
-V
GND
RX2
-V
+V
+TX