7 Connecting Telephones and Adjunct Systems:

Install Circuit Protection

Over-voltage and sneak fuse protection measures are necessary for the safe operation of the G700 Media
Gateway system.

Over-Voltage and Sneak-Current Protection

Out-of-building installations of telephones or other standard (tip/ring) devices/terminals that connect
to the Avaya G700 Media Gateway Media Modules require over-voltage and sneak current protection
at both building entry points. Sneak current protectors must have a maximum of 350 mA and a
minimum voltage rating of 600V. The following devices have been evaluated or tested and approved
to protect the Media Modules from over-voltages and sneak current protection:
• Avaya MM712 DCP: either 146E IROB (In-Range Out-of-Building) or 4C3S-75 solid state
protectors for surge and sneak current.
• Avaya MM710 T1/E1: over-voltage and sneak protection for the Avaya MM710 T1/E1 Media
Module is provided on the Media Module itself.
• Avaya MM711 Analog: analog trunks use the 507B or 110-SCP-9 sneak current protectors. Over-
voltage protection is normally provided by the local telephone company. Analog voice terminals
use one of the following types of combined over-voltage and sneak current protection:
- Gas tube with heat coil: 4B1E-W
- Solid state with heat coil: 4C1S
- IROB: 146C (4-lines) or 146F (25-lines)
!
WARNING:
Only service-trained personnel are to install these circuit protection devices.

IA 770 INTUITY AUDIX Messaging Application

Note: For complete information on IA 770 INTUITY AUDIX Installations, including the
S8300 hard drive replacement, see the IA INTUITY AUDIX documentation on the
G700 Media Gateway and S8300 Media Server Documentation CD-ROM, 555-
234-800, or the IA 770 INTUITY AUDIX Messaging Application Installation
Checklist and Instructions, 585-313-159. Both of these documents are included in
the IA 770 INTUITY AUDIX Messaging Application Technician Kit.
The IA 770 INTUITY AUDIX Messaging Application runs only on a G700 Media Gateway controlled by
an S8300 Media Server.
242
IA 770 INTUITY AUDIX Messaging Application
Installation and Upgrades for the G700 with an S8300/S8700
555-234-100 — Issue 2 — October 2002