Connecting An Analog Station Or 2-Wire Digital Station - Avaya S8500 Manual

Media server, media gateway
Hide thumbs Also See for S8500:
Table of Contents

Advertisement

Installing and wiring telephones and trunks
Figure 89: 400B2 Adapter connecting to a modular plug
Figure notes
1
Flush-Mounted Information Outlet
2
Surface-Mounted Information Outlet
3
To Individual Power Unit
Connecting an analog station or 2-wire digital
station
This example is typical of the 2-wire digital stations (2420, 64xx, 302D), 2-wire analog stations (2500),
analog central office (CO) trunks, direct inward dial (DID) trunks, and external alarms. See
2500-type analog telephone wiring,
1
Choose a peripheral to connect (such as a 2-wire digital station).
2
Choose the media module to use and its media gateway and slot number. For example: MM711
Analog Media Module, Media Gateway 002, Slot V2.
3
Choose a port circuit on the MM711 Media Module, for example port 03.
4
Install cross-connect jumpers to connect the pins from the 2-wire digital station to the appropriate
pins on the MM711 Media Module.
chart for two-wire stations.
5
Administer using Administrator's Guide for Avaya Communication Manager.
236
on page 237.
Installing the Avaya S8500 Media Server with an Avaya G650 Media Gateway
4
400B2 Adapter
5
To Telephone
6
Destination Service Access Point (DSAP)
Power Cord
Table 21, Station pinout chart,
r749428 KLC 060396
Figure 90,
on page 237 shows a printout
December 2003