Analog Station Or 2-Wire Digital Station Example; Analog Tie Trunk Example - Avaya CMC1 Installation, Upgrades And Additions

Table of Contents

Advertisement

Installing and Cabling the Cabinets

Analog Station or 2-Wire Digital Station Example

This example is typical of the 2-wire digital stations,2-wire analog stations, analog CO trunks,
DID trunks, and external alarms. See
Figure 33: 2500-Type Analog Telephone Wiring
Figure notes:
1. 2500-type analog station
To wire analog telephone equipment:
1. Choose a peripheral to connect (such as a 2-wire digital station).
2. Choose the port circuit pack to use and its carrier and slot number. For example, TN2183
Analog Line, Cabinet 1, Carrier C, Slot 1.
3. Choose a port circuit on the port circuit pack, for example port 3.
4. Install cross-connect jumpers to connect the pins from the 2-wire station to the appropriate
pins on the port circuit pack.
5. Administer using Administrator's Guide for Avaya Communication Manager.

Analog Tie Trunk Example

Figure 34: Analog Tie Trunk Wiring
Figure notes:
1. External trunk or adapter
88 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
Figure
33.
T
2
3
R
2500wire RBP 040596
2. 2-wire analog line circuit pack
T1
26
1
R1
T11
27
R11
2
E1
28
M1
3
2. Tie trunk circuit pack
28
T3
03
R3
29
T2
4
R2
T12
30
R12
5
E2
31
6
M2
tie_wire RBP 040596