Start Up Multivantage Software (Only When The S8300 Is An Lsp); Complete The Upgrade Process (Only When S8300 Is Primary Controller) - Avaya G700 Installation And Upgrades

Hide thumbs Also See for G700:
Table of Contents

Advertisement

5 Upgrading an Existing G700 with an S8300 (Primary Controller or Local Survivable Processor):
Start up MultiVantage Software (Only When
the S8300 is an LSP)
Note: Since you shut down the MultiVantage Software on the S8300 LSP, you must start
it again. Only do this when the S8700 primary controller upgrade is complete.
Return to your telnet window.
1.
At the S8300 Linux command line, type start -a and press
2.
The S8300 starts up MultiVantage Software.
End
Complete the Upgrade Process (Only When
S8300 is Primary Controller)
Check Media Modules
Begin
Type list configuration all and press Enter.
1.
2.
Verify that the software is communicating with all media modules and that all media modules are
listed in the reports.
Make test telephone calls to verify that MultiVantage™ Software is working.
3.
Enable Scheduled Maintenance
Begin
1.
Type change system-parameters maintenance and press Enter.
Ensure that the Start Time and Stop Time fields' administration is the same as before the
2.
upgrade.
Enable TTI
Begin
Note: Perform this step only if you disabled TTI before the upgrade.
1.
Type change system-parameters features and press Enter to change the TTI field back to its
value before the upgrade.
Go to the second page and set the Terminal Translation Initialization (TTI)
2.
Enabled? field to y and press Enter.
216
Installation and Upgrades for the G700 with an S8300/S8700
555-234-100 — Issue 2 — October 2002
EN TER
.

Advertisement

Table of Contents
loading