5 Upgrading an Existing G700 with an S8300 (Primary Controller or Local Survivable Processor):
Check TTI Status
Begin
1.
Type status tti and press Enter.
Check the Percent Complete field.
2.
If the value is 100, then go on to the next section.
If the value is less than 100, repeat Steps 1 and 2 until the Percent Complete field is 100.
Busy Out Trunks
Begin
Busy out trunks that were busied out before the upgrade (see
1.
Resolve Alarms
Begin
1.
Click View Current Alarms to examine the alarm log.
Resolve new alarms since the upgrade through the MultiVantage Software using the appropriate
2.
maintenance book.
Check for Translation Corruption
Begin
1.
Type newterm and press Enter.
If you do not get a login prompt and see the following message:
Warning: Translation corruption detected
follow the normal escalation procedure for translation corruption before continuing the upgrade.
Back up the System
Begin
1.
Back up the system as you did before the upgrade.
Installation and Upgrades for the G700 with an S8300/S8700
555-234-100 — Issue 2 — October 2002
Record All
Busyouts).