Avaya G700 Installation And Upgrades page 198

Hide thumbs Also See for G700:
Table of Contents

Advertisement

5 Upgrading an Existing G700 with an S8300 (Primary Controller or Local Survivable Processor):
Check TTI Status
Begin
At the SAT prompt, type status tti and press Enter.
1.
2.
Check the Percent Complete field.
If the value is 100, then go on to the next section.
3.
4.
If the value is less than 100, repeat Steps 1 and 2, until the Percent Complete field reads
100.
Disable Scheduled Maintenance
Begin
To prevent scheduled daily maintenance from interfering with the upgrade:
At the SAT prompt, type change system-parameters maintenance and press Enter.
1.
If scheduled maintenance is in progress, set the Stop Time field to 1 minute after the current
2.
time.
or
If scheduled maintenance is not in progress, set the Start Time field to a time after the
upgrade will be completed.
For example, if you start the upgrade at 8:00 P.M. and the upgrade takes 90 minutes, set the
Start Time field to 21:30.
!
CAUTION:
If you do not disable Alarm Origination, the system can generate alarms, resulting in
unnecessary trouble tickets.
3.
Type neither in the Alarm Origination to OSS Numbers field and press Enter.
Check for Translation Corruption
Begin
At the SAT prompt, type newterm and press Enter.
1.
If you do not get a login prompt, but instead see the following message
Warning: Translation corruption detected
then follow the normal escalation procedure for translation corruption before continuing the
upgrade.
198
Installation and Upgrades for the G700 with an S8300/S8700
555-234-100 — Issue 2 — October 2002

Advertisement