5 Upgrading an Existing G700 with an S8300 (Primary Controller or Local Survivable Processor):
4.
Plug the other end of the RS-232 cable into the RJ-45 jack on the DB-9 adapter cable.
Connect the other end of the DB-9 adapter cable to the 9-pin serial port on your laptop.
5.
6.
Use a serial-connection program such as HyperTerminal to access the P330 stack processor.
Log in to the Avaya P330 (Layer 2 Switching Processor) Command Line Interface
Begin
1.
Launch Windows® HyperTerminal or any other terminal emulation program.
Note: If you are upgrading an S8300 LSP remotely, you connect using telnet and the IP
address of the P300 Stack Master.
Note: For most Windows-based PCs, you access the HyperTerminal program from the
Start menu by selecting Programs , then Accessories .
Choose Call - Connect or the appropriate call command for your terminal emulation program.
2.
Login at the Welcome to Avaya P330 screen.
3.
Login: xxx from the planning documentation
Password: xxx from the planning documentation
You are now logged-in at the Supervisor level. The prompt appears as P330-1(super)#. In order
to use the commands necessary to configure the P330 Stack Processor, you must reset to the
Configure level.
Type configure
4.
The prompt appears as P330-1(configure)#.
End
Note:
To check the syntax of a command in the command line interface, type as much of the command
as you know followed by help. For example:
P330-1(configure)#> set help
you will be given the current list of set commands available. If you type:
P330-1(configure)#> set interface help
you will be given a much more restricted list of command possibilities that address the possible
interfaces to be set.
For a complete list of command line interface commands, refer to the "Avaya™ P330 User's Guide".