Start-Up
4.4

Function diagrams

Notes on the function diagrams:
The function diagrams on the two following sheets show the controller structure of the infeed/regenerative
feedback unit.
A value in brackets for a parameter indicates the factory setting of the parameter in question.
Switch positions drawn are the factory setting.
These function diagrams also contain parameters that are not listed in the parameter list (Chapter 5) of these
operating instructions. They are the expert parameters that are only visible at the PMU if P051 = 3 and
P799 = 4. These expert parameters contain a useful factory setting and must not usually be altered.
Not only the parameter but also the most important "connectors" (Kxxx) are drawn into the function diagrams.
Connectors can be seen as "digital measuring points" of internal controlled variables or memory locations (e.g.
DC link voltage K287, DC link current K114, control angle K100). The connectors are only used for factory
internal diagnostic purposes and are not described in more detail in these operating instructions. A hexadecimal
display of a single connector value is possible using the expert parameters P787 and r786 on the PMU by
parameterizing the number of the connector to be displayed at parameter r786 at P787.
4-48
AoteWell LTD
AoteWell Automation Sales Team
Buy Siemens PLC HMI Drives at AoteWell.com
Sales@aotewell.com
Siemens AG
6SE7087-6AK85-1AA0
Rectifier/Regenerating Unit
Operating Instructions
https://www.aotewell.com
09.02

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents