Battery Replacement

About

This procedure provides instruction to determine the condition of the battery to remove and
install the Battery.

Determining the battery condition

Use the System Tests menu BATTERY TEST to measure the battery voltage and determ-
ine the battery condition.
BATTERY TEST
Format
XX.X VDC YY
where
XX.X is the measured battery voltage in VDC (nominal 12.6 - 14.6 Vdc).
VDC: DC
Y is the information suffix:
     C: external
      L: Battery is low (less than 11.4 volts).
     CL: Charger is connected and battery is low.

Battery Fuse

The battery inline fuse holder is part of the battery assembly cable attached to the battery
positive terminal. To remove the fuse, twist the fuse holder top cap and remove.
Fuse Type: Inline 10 Amp slow blow fuse, .25" diameter
1
Direct Current: electrical current that only flows in one direction.
2
Alternating Current: electric current which periodically reverses direction between positive
and negative polarity.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
1
volts
2
AC
charger connected.
6 Replacement Procedures
Battery Replacement
Page 93