3. SIGNALS AND WIRING
3.3.3 CNP1 and CNP2 wiring method
Use the supplied servo amplifier power supply connectors for wiring of CNP1 and CNP2.
(1) Servo amplifier power supply connectors
<Applicable cable example>
Wire size: 0.2 to 2.5mm
Cable finish OD: to
POINT
Refer to section 11.5, for the wire sizes used for wiring.
(AWG24 to AWG12)
2
4mm
Connector for CNP1
FKC2,5/ 9-ST-5,08
(Phoenix Contact)
Connector for CNP2
FKCT 2,5/ 2-ST-5,08
(Phoenix Contact)
3 - 10
Servo amplifier
CNP1
CNP1
CNP2
CNP2