13. POSITIONING MODE
13.10 Single-step feed usage in the test operation mode
This section provides the usage of single-step feed using MR Configurator.
Operation is performed in accordance with the preset point table No./program No.
Click "Test" on the menu bar and click "Single-step Feed" on the menu.
Clicking displays the confirmation window for switching to the test operation mode.
POINT
The single-step feed is supported by servo amplifier with software version B0
or later, and MR Configurator with software version C4 or later.
The servo motor will not operate if the forced stop (EM1), forward rotation
stroke end (LSP) and reverse rotation stroke end (LSN) are off. Make
automatic ON setting to turn on these devices or turn on between DOCOM.
(Refer to section 4.4.2.)
13 - 91