13. POSITIONING MODE
(2) List of details
No.
Symbol
PD20
*DOP1 Function selection D-1
Select the stop processing at LSP/LSN OFF or when the software limit is
detected, the base circuit status at reset (RES) ON and the operation during
tough drive (MTTR).
Name and function
0
Stop processing at LSP/LSN OFF or when the
software limit is detected
0: Sudden stop (Home position is not erased.)
1: Slow stop (Home position is not erased.)
Selection of base circuit status at reset (RES) ON
0: Base circuit switched off
1: Base circuit not switched off
Operation selection during tough drive (MTTR)
0: MTTR turns ON during the instantaneous
power failure tough drive
1: MTTR turns ON during the overload tough drive
or the instantaneous power failure tough drive
13 - 79
Initial
Setting
Unit
value
range
0000h
Refer to
the name
and
function
filed.