Positioning Operation - Mitsubishi Electric MELSERVO-JN Series Instruction Manual

General-purpose ac servo, general purpose interface servo amplifier/motor
Table of Contents

Advertisement

5. DISPLAY AND OPERATION SECTIONS

5.10.3 Positioning operation

With no command given from the command device, positioning operation can be executed once.
(1) Operation
a)
b)
c)
d)
e)
f)
g)
a) Motor speed [r/min]
Enter the servo motor speed into the "Motor speed" input field.
b) Accel/decel time [ms]
Enter the acceleration/deceleration time constant into the "Accel/decel time" input field.
c) Move distance [pulse]
Enter the moving distance into the "Move distance" input field.
d) LSP/LSN automatically turned ON
When setting the external stroke signal to automatic ON, click the check box to make it valid. When it
is not checked, turn ON LSP/LSN externally.
e) Move until the initial Z-phase signal of the move distance in the move direction is turned ON.
Movement is made until the initial Z-phase signal of the move distance in the move direction is turned
ON.
POINT
MR Configurator is required to perform positioning operation.
Turn ON the forced stop (EM1) when performing positioning operation.
During positioning operation, the "UP" and the "DOWN" buttons are invalid.
5 - 26
h)
i)
j)
k)
l)
m)
n)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-jn-10aMr-jn-20a1Mr-jn-20aMr-jn-40aMr-jn-10a1

Table of Contents