Wiring CNP1, CNP2, and CNP3

• For the wire sizes, refer to the following.
Page 217 Selection example of wires
• When wiring, remove the power connectors from the servo amplifier.
• Insert only one wire or ferrule into each wire insertion hole on each power connector.
To wire to CNP1, CNP2 and CNP3, use the servo amplifier power connectors that came with the amplifier.
Connector
■MR-J5-10_ to MR-J5-100_
CNP1
CNP2
CNP3
Connector Receptacle assembly
CNP1
06JFAT-SAXGDK-K7.5 (LA)
CNP2
05JFAT-SAXGDK-K5.0 (LA)
CNP3
03JFAT-SAXGDK-K7.5 (LA)
■MR-J5-200_/MR-J5-350_
CNP1
CNP2
CNP3
Connector Receptacle assembly
CNP1
06JFAT-SAXGFK-XL (LA)
CNP2
05JFAT-SAXGDK-H5.0 (LA)
CNP3
03JFAT-SAXGFK-XL (LA)
Applicable wire
Size
Insulator OD
AWG 18 to 14
3.9 mm or less
Applicable wire
Size
Insulator OD
AWG 16 to 10
4.7 mm or less
AWG 18 to 14
3.9 mm or less
AWG 16 to 10
4.7 mm or less
Stripped length
Open tool
[mm]
9
J-FAT-OT-K
Stripped length
Open tool
[mm]
11.5
J-FAT-OT-EXL
9
11.5