3. SIGNALS AND WIRING
(2) Termination of the wires
(a) Solid wire
The wire can be used just by stripping the sheath.
(b) Twisted wire
1) Inserting the wires directly to the terminals
Use the wire after stripping the sheath and twisting the core. At this time, take care to avoid a short
caused by the loose wires of the core and the adjacent pole. Do not solder the core as it may cause
a contact fault.
2) Putting the wires together using a ferrule
Use a ferrule as follows.
Cable size
[mm
2
]
1.25/1.5
2/2.5
Cut off the exceeding wire from the tip of the ferrule, leaving 0.5mm or less.
When using the ferrule for two wires, plug the wires in a direction in which insulating sleeves do not
interfere the adjacent poles.
AWG
For one wire
16
AI 1,5-10 BK
14
AI 2,5-10 BK
Sheath
Core
Approx. 10mm
Ferrule type
For two wires
AI-TWIN 2
1,5-10 BK
0.5mm or shorter
Crimp
Crimp
3 - 11
Crimping tool
Manufacturer
CRIMPFOX ZA 3
Phoenix Contact