Operation Example ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ - Mitsubishi Electric MELSERVO-JN Series Instruction Manual

General-purpose ac servo, general purpose interface servo amplifier/motor
Table of Contents

Advertisement

5. DISPLAY AND OPERATION SECTIONS
5.7.2 Operation example
(1) Parameter of 3 or less digits
The following example shows the operation procedure performed after power-on to change the control
mode (parameter No. PA01) to the internal speed control mode. Press "MODE" to switch to the basic
setting parameter screen.
To shift to the next parameter, press the "UP" or the "DOWN" button.
When changing parameter No. PA01 setting, change its set value, then switch power off once and switch it
on again to make the new value valid.
POINT
When the set value of a specified parameter is changed and entered, the entered
set value is displayed. The set value can be cancelled by pressing the "MODE"
button for 2[s] or longer immediately after entering the value. Then, the previous
set value is displayed.
The parameter number is displayed.
Press UP or DOWN to change the number.
Press SET twice.
The set value of the specified parameter number blinks.
Press UP twice.
During blinking, the set value can be changed.
Use UP or DOWN.
(
Press SET to enter.
2: Internal speed control mode)